Renesas Electronics /R7FA6M4AF /SYSC /OSCSF

Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text

Interpret as OSCSF

7 43 0 0 00 0 0 0 0 0 0 0 0 (0)HOCOSF 0 (0)MOSCSF 0 (0)PLLSF 0 (0)PLL2SF

PLL2SF=0, PLLSF=0, MOSCSF=0, HOCOSF=0

Description

Oscillation Stabilization Flag Register

Fields

HOCOSF

HOCO Clock Oscillation Stabilization Flag

0 (0): The HOCO clock is stopped or is not yet stable

1 (1): The HOCO clock is stable, so is available for use as the system clock

MOSCSF

Main Clock Oscillation Stabilization Flag

0 (0): The main clock oscillator is stopped (MOSTP = 1) or is not yet stable

1 (1): The main clock oscillator is stable, so is available for use as the system clock

PLLSF

PLL Clock Oscillation Stabilization Flag

0 (0): The PLL clock is stopped, or oscillation of the PLL clock is not stable yet

1 (1): The PLL clock is stable, so is available for use as the system clock

PLL2SF

PLL2 Clock Oscillation Stabilization Flag

0 (0): The PLL2 clock is stopped, or oscillation of the PLL2 clock is not stable yet

1 (1): The PLL2 clock is stable